The Dräger Polytron, 8200 CAT is an advanced explosion-proof transmitter for the detection of flammable gases in the lower explosion limit (LEL).

It uses a catalytic bead DrägerSensor, Ex that will detect most flammable gases and vapours. In addition to a 3-wire 4 to 20-mA analogue output with relays it also offers HART,, Modbus and Fieldbus protocols, making it compatible with most control systems.

Οφέλη

Fast and stable – the DrägerSensor® Ex

The built-in DrägerSensor, Ex is based on the proven catalytic bead measuring principle. It has excellent long-term stability with outstanding poison resistance. And this is the reason for its durability. Due to the novel gas inlet opening, the sensor responds to gas in only a few seconds. This allows you to react immediately with countermeasures and prevent the development of a flammable atmosphere.

Easy device management via digital communication
The Dräger Polytron 8200 is equipped with digital interfaces allowing for quick and easy remote interrogation of the transmitter’s state. Integration with existing asset management systems such as PACTware is possible via DTM. In addition to the common HART, communication system, the fieldbus interfaces PROFIBUS, PA, FOUNDATION fieldbus H1, and Modbus RTU are also available.
Same design, same operating principle

The Dräger Polytron 8200 belongs to the Polytron 8000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements. The large graphic backlit display shows status information clearly and in an easy to use format. The measured gas concentration, selected gas type, and measuring unit are displayed during normal operation. Colored LEDs (green, yellow and red) provide additional alarm and status information.

Three relays for controlling external equipment

Upon request, the Dräger Polytron 8200 can also be supplied with three integrated relays. This enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm. Audible alarms, signal lights or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller.

Safe, robust housing for every application

Polytron 8200 features a Class I, Div. 1 rated explosion proof enclosure made from aluminium or stainless steel, making it suitable for a wide range of environmental conditions. A protection type “e” version includes a convenient docking station which allows installation in hazardous atmospheres without running conduit (where approved) and this also facilitates pre-assembly.

Make the impossible possible with the remote sensor

The remote sensor connection housing allows you to install the sensor separately from the transmitter. This allows you to simply place the sensor closer to the gas cloud in hard-to-reach locations. The display remains visible at eye level. Since the sensor is connected via an intrinsically safe connection, no conduit cabling is required. The connection also allows ‘hot replacement’ of the sensor in the hazardous area.

Data logger

The Polytron 8200 has a data logger, which records measuring and event data from prior years.

Εικόνες και Βίντεο

Βρείτε αυτό το προϊόν

Βασικά Στοιχεία

Fixed Type

Transmitter

Cable entry

M20 or 3/4" NPT

ΑΝΑΛΥΣΗ

Ναι

Intrinsic Safety

Νο

Flameproof

Ναι

Increased Safety

Ναι

SIL

Ναι

4-20 mA

Ναι

Bus

Ναι

HART®

Ναι

Wireless

Όχι

Τεχνικά Δεδομένα

ΑΝΑΛΥΣΗ

Ναι

ΒΑΡΟΣ

4 Kg

ΔΙΑΣΤΑΣΕΙΣ (Β * Π * Υ)

0.28×0.15×0.13 m

ΒΑΘΜΟΣ ΠΡΟΣΤΑΣΙΑΣ

IP65/66/67

Power Supply

10 to 30 V DC, 3-wire

Temperature (operation)

-40°C – 80°C

Humidity

0 to 100 % r.h., non-condensing

Pressure (hPa)

700 – 1300

Housing Material

Epoxy coated copper-free aluminum or stainless steel SS316 L

Εγκρίσεις

ATEX

Ναι

IECEx

Ναι

CE

Ναι

GOST (EAC)

Ναι

Performance approval

Ναι

Shipping approval

Ναι

UL

Ναι

CSA

Ναι

FM

Όχι

Δεδομένα Προϊόντος

Λήψη

More than the sum Brochure

Λήψη

Explosion Protection Brochure

Λήψη

Μετάβαση στο περιεχόμενο

Σφάλμα στη βάση δεδομένων: [Unknown column 't.term_order' in 'order clause']
SELECT DISTINCT `t`.* FROM `wp_terms` AS `t` LEFT JOIN `wp_term_taxonomy` AS `tt` ON `tt`.`term_id` = `t`.`term_id` LEFT JOIN `wp_term_relationships` AS `tr` ON `tr`.`term_taxonomy_id` = `tt`.`term_taxonomy_id` WHERE ( `tt`.`taxonomy` = 'region' ) ORDER BY `t`.`term_order` ASC, `t`.`name`, `t`.`term_id` LIMIT 0, 15